It is necessary to compensate the effect of temperature on the phone output power. To monitor this environment change, the temperature measurement is done by using a NTC resistor. A factor table is used for temperature compensation. The table contains common values for all power levels and operating modes. The table values are defined without factory measurements. The temperature is measured and right compensation value is added to the TXC-value. The requirement for compensation update is for...

Flash Loading Adapter FLA Sales Pack

The Flash Loading Adapter FLA-5 is used with the Service Battery BBD-3 and Service Cable SCH-5. Power is supplied to FLA-5 from the Flash Security Box TDF-4 via the DC cable PCC-1B, (The PCC-1B cable can be replaced with a Travel Charger ACH-6), and is connected to the Flash Prommer FPS-4S with the cable AXS-5. - Installation software for FPS-4 Flash Loading Adapter FLA-5 0080178

Modes of Operation

The UT4U UT4RM operates in seven cellular modes and a local mode for service - Analog Control Channel (ACCH) 800 MHz Mode, - Analog Voice Channel (AVCH) 800 MHz Mode, - Digital Control Channel (DCCH) 800 MHz Mode, - Digital Traffic Channel (DTCH) 800 MHz Mode, - Digital Control Channel (DCCH) 1900 MHz Mode, - Digital Traffic Channel (DTCH) 1900 MHz Mode, - Locals mode, used by Production and After Sales. On analog control channel mode the phone receives continuous signalling messages on Forward...

Vcxo

Both MAD and CCONT include a watchdog, and both use the 32 kHz sleep clock. The watchdog in MAD is the primary one, and this is called SW-watchdog. MCU has to update it regularly. If it is not updated, logic inside MAD gives reset to mAd. After the reset, MCU can read an internal status bit to see the reason for reset, whether it was from MAD or CCONT. The SW-watchdog delay can be set between 0 and 63 seconds at 250 millisecond steps and after power-up the default value is the max. time. MAD...