HW CHANGES SUMMARY FOR GF - BOARD

CONFIDENTIAL 12 (48)

NSE-8/9 Repairhints

Version 5.0 Approved

Date: 05.09.2001

PCB-Version

HW-

Delete

Add

Remarks

changes

GF7_

.17

3.00 =>

N114

(4219941)

V114

(4219941)

Improvement of amplitude

3.02

C153 27pF

(2320546)

C153 22pF

(2320544)

of 32kHz oscillator

GF7_

.17

3.02 =>

C232 27pF

(2320546)

To get a better TDMA-noise

3.05

C233 27pF

(2320546)

uplink performance

C242 27pF

(2320546)

C243 27pF

(2320546)

GF7_

.17

3.05 =>

C148 100pF

(2320560)

C148 47pF

(2320552)

To improve the start up of

3.06

C153 22pF

(2320544)

C153 18pF

(2320604)

32kHz oscillator

GF7_

.18

4.00 =>

C232 27pF

(2320546)

To get a better TDMA-noise

4.05

C233 27pF

(2320546)

uplink performance

C242 27pF

(2320546)

C243 27pF

(2320546)

GF7_

.18

4.05 =>

C148 100pF

(2320560)

C148 47pF

(2320552)

To improve the start up of

4.06

C153 22pF

(2320544)

C153 18pF

(2320604)

32kHz oscillator

GF7_

.18

4.06 =>

71MHz Filter

(4511109)

71 MHz Filter

(4511161)

4.10

R717 220Q

(1430734)

R717 330Q

(1430740)

R718 220Q

(1430734)

R718 330Q

(1430740)

R701 47Q

(1430744)

R701 5.6kQ

(1430772)

R606 2.7kQ

(1430832)

R606 5.6kQ

(1430772)

C749 1.5pF

(2320516)

C749 1.8pF

(2320518)

C617 68pF

(2320556)

C617 82pF

(2320558)

C618 68pF

(2320556)

C618 82pF

(2320558)

L600 180nH

(3643037)

L600 220nH

(3643079)

L601 180nH

(3643037)

L601 220nH

(3643079)

L701 330nH

(3645031)

L701 390nH

(3640077)

GF7_

.18

4.10 =>

D300 MAD V5

(4370489)

D300 MAD V9

(4370591)

New CCONT Version 2I

4.

C145 100pF

(2320560)

C149 2.2 pF

(2320915)

New MAD V9 (C07)

15

C320 10nF

(2320620)

N100 CCONT2I

(4370467)

C149 2.2pF

(2320915)

N100 CCONT2IH

(4370393)

GF7_1

8 =>

4.06 =>

R104 10Q

(1430700)

R619 18Q

(1430708)

New MAD Version 9 (C07)

GF7_

_20

5.00

R619 22Q

(1430710)

R727 1.8kQ

(1430760)

R605 1kQ

(1430754)

C205 10nF

(2320805)

R727 1.5kQ

(1430758)

D300 MAD V9

(4370591)

R135 330kQ

(1430816)

R630 22Q

(1430710)

C307 1nF

(2312401)

R320 100Q

(1430726)

C613 27pF

(2320546)

R620 270Q

(1430738)

C205 33nF

(2320783)

R621 270Q

(1430738)

C122 10MF

(2610003)

R335 330kQ

(1430816)

D300 MAD V5

(4370489)

R314 0Q

(1430690)

R327 1kQ

(1430754)

C122 1|F

(2312401)

C318 1|F

(2312401)

C245 1|F

(2320481)

C332 27pF

(2320546)

C650 27pF

(2320546)

C320 10nF

(2320620)

IMOKIA CONFIDENTIAL 13 (48)

NSE-8/9 Repairhints

Customer Care Europe & Africa Version 5.0 Approved Technical Services Training Group Date: 05.09.2001

GF7_20

5.00 => 5.15

C145 100pF (2320560) C320 10nF (2320620) C149 2.2pF (2320915) N100 CCONT 2IH (4370393)

C149 2.2pF (2320915) N100 CCONT 2I (4370467)

New CCONT version 2I

GF7_20

5.15 => 5.16

R508 47Q (1430718) R319 680KQ (1430826)

R508 68Q (1430722)

Improvements in RF/PCN (R508) Changed interrupt level for CARDDETX in BB (R319)

GF7_20

5.16 => 5.30

N200 COBBA 3.1 (4370575)

N200 COBBA 4.1 (4370643)

New COBBA Version 4.1

GF7_20

5.30 => 5.31

Z601 Filter 902MHz (4511015)

Z601 Filter 902MHz (4511155)

New TX-Filter

GF7_20

5.31 => 5.86

N100 CCONT 2M (4370467)

N100 CCONT 2M (4370719)

New CCONT version 2M

GF7_20

5.89 => 5.90

L103 60R/100MHz (3203717)

L103 470R/100MHz (3203737)

L103 changed, which improves 600 KHz modulation spectrum

GF7_20

5.87 => 5.94

R514 10Q (1430700) R513 470Q (1430744) R515 470Q (1430744) N502 RF Ampl. (4340263)

R514 47Q (1430718) N502 RF Ampl. (4340263)

New PCN PA buffer RFMD=> damp adaption: (R513,R514,R515)

GF7_22

New board with selective OSP

IMOKIA CONFIDENTIAL 14 (48)

NSE-8/9 Repairhints

Customer Care Europe & Africa Version 5.0 Approved

Technical Services Training Group Date: 05.09.2001

PHONE DOES NOT SWITCH ON

At first always check mechanical appearance of battery connectors X101/X102 if bent or dirty etc. -defect connectors could cause additional faults like "not charging" or the phone switches off intermittently.

Does not switch on with battery (nor with service battery)

Check if phone works properly in service jig. Check if BTEMP AD value is in range of 300.

Check battery connectors X101 / X102 for broken solderings or bent spring contacts (see pictures below). Check if phone works also after connecting LCD module in jig (short circuit in VBB line from LCD possible).

X504 related fault

Check if connector X504 has its correct position - especially after rework in its area.

If it is misplaced or bent, it could cause possible short circuits to D - Cover with throughholes.

POWER switch S416 faulty

Check mechanical condition of S416.

Check if PWRON at R413 drops to 0V during pressing power switch. Change powerswitch S416 or continue with CCONT chapter on page#17.

L102 broken/poor soldered

Check soldering of L102. Check resistance of L102 = 0Q. Resolder coil or change if necessary.

See the different versions of coil in HW changes chapter on page#9.

VB line faulty

Check battery voltage VB 2.7VDC at L102.

Check VB 2.8VDC at R132.

Check connection (0Q) between R132/L102.

See HW changes chapter on page#9 for additional PCB protection.

IMOKIA CONFIDENTIAL 15 (48)

NSE-8/9 Repairhints

Customer Care Europe & Africa Version 5.0 Approved

Technical Services Training Group Date: 05.09.2001

DC/DC Converter V105 faulty

Check the difference between V101 cathode 3.2VDC / anode 2.6VDC. Check at V105 - pin 4, 5, 12, and 13: switching frequency 600kHz. Check 1.2VDC at V105, pin 15.

Check at V105, pin3: 0V. If not, check the respective voltage dividers R131, R132, R134, R143, R144. If all ok - change V105.

FLASH D301 / SRAM D302 related faults

Check if the current consumption is approximately 20mA.

Try to flash the phone - if this does not work go to chapter "FLASH update not possible" on page#30.

Check also near the service contacts on the PCB - If any component is missing (like on picture below) - flashing will not work!

Torn off components are the result of sliding the phone on the service battery - the contacts can be damaged, too. NOTE: Always handle the phone in combination with the service battery with care to prevent those failures!

Customer Care Europe & Africa Technical Services Training Group

Date: 05.09.2001

G701 faulty

Check VCC 2.8VDC at C750 (Phone must be set in local mode).

Check control voltage (AFC) 0.1 - 2.3V at C715.

Check 13MHz reference frequency ±50 Hz (900mVpp) at R743.

NOTE:

If you have to change the oscillator, pay attention to use the correct one - also see HW changes chapter on page#8

'false

¿cBffecti

800,00 600,00 400,00 200,00 mV 0,00 -200,00 -400,00 -600,00 -800,00

MHz at R 743

.11 II

INI

1 1 1 1

1 1 1 1

MIL

-1 i i i

i i M

lili

II 1 1

MIL

1111 •>

1 1 1 1

-i

\

/

/

\

"INI

MM

Il II

/

i i i r

\

1 1 M

1 l'I 1

Mil

IH 1

-Il II

1 1 1 1

/

MIL

1 1 M

J

Mil

\

Vv

/

\

\ /

/

1 1 1 1

1 1 1 1

"MM

I il 1

il M

1 M 1

M II-

-m m

lili

M II

1 M 1

20 ns/Div

Nanne

= Active Channel 1

Date

= 20.06.01

Time

= 07:50:45

Y 5 cale

= 200

mWDiv

Y At 50%

= 0,00

mV

X 5 cale

= 20

ns/Div

X At OZ

= 0

ns

X Size

= 512

(512)

Maximum

= 468,22

mV

Minimum

= -424,63

20 ns/Div

CEU 11

ITFP

Marker 13.0000 MHz

I.ÛÛÛÛ MH7-

-25.278 dBm

/

\

/

\

/

\

/

\

1

\

/

\

/

\

/

\

CF Step AUTO /MNL

Peak*CF

CENTER 13.0000 MHz SPAN 200 kHz *RBW 10 kHz *VBW 1 kHz *SWP EOO ms

Freq

Center

S-tar-t

S-top

CF Step AUTO /MNL

Peak*CF

CENTER 13.0000 MHz SPAN 200 kHz *RBW 10 kHz *VBW 1 kHz *SWP EOO ms

Customer Care Europe & Africa Technical Services Training Group

Date: 05.09.2001

MAD D300 faulty

Check 32.768 kHz SLEEPCLK squarewave at C145 3Vpp.

Check 13MHz RFC at C301 900 mVpp.

Check VBB 2.8 VDC at C117.

Check SLEEPX 2.8 VDC at J340.

Check PURX 2.8 VDC at R303.

CCONT N100 faulty

Check at R413, if 3.2VDC drops to 0V during pressing powerswitch.

Check SLEEPCLK 32.768kHz squarewave at C145: 3Vpp.

Check VBB 2.8VDC at C117.

Check Vref 1.5VDC at C123.

Check PURX 2.8VDC at R303.

Check VXO 2.8 VDC at C102.

Customer Care Europe & Africa Technical Services Training Group

B100 faulty

Check 32.768kHz sinewave at C153 - 600mVpp.

Check Sleepclock area: C147, C148, C149, C153 and R121-R124.

Check 32.768kHz squarewave at C145 - 3Vpp.

Date: Q5.Q9.2QQ1

400,00 300,00 200,00 100,00 mV 0,00 -100,00 -200,00 -300,00 -400,00

32.768 kH

z at

C133

.m m

1 1 m

1 1 1 1

mil

mil

-mil

i i m

i i i i

i i i i

i i i i.

c 1111

/

/

/

\

f

1

/

I

il ii

J

i i i i

"mm

1 1 1 1

m ii

i m i

m ii-

"il ii

i m i

m ii

mil

2,000 1,500 1,000 0,500 V 0,000 -0,500 -1,000 -1,500

10 jis/Div 32.768 kHz at C145

-i i i i

i i i i

i i i i

i i i i

mil

.i i i i

i i i i

i i i i

i i i i

i i i i-

i i

I r

i

I I

"il ii

i i ii

m ii

m i i

m ii-

-m m

i m i

i i

m i i

Nanne

= Active Channel 1

Date

= 28.05.01

Time

= 14:46:47

Y Scale

= 100

mWDiv

Y At 50%

= 0,00

mV

X Scale

= 10

l^s/Div

X At 0Z

= 0

X Size

= 512

(512)

Maximum

= 273,31

mV

Minimum

= -233,50

mV

Name

= Active Channel 1

Date

= 28.05.01

Time

= 14:40:03

Y Scale

= 500 mV/Div

Y At 50%

= 0,00 mV

X Scale

= 10 \i$/D\v

X At 0Z

0 \i.$

X Size

= 512 (512)

Maximum

= 1,453 V

Minimum

Customer Care Europe & Africa Technical Services Training Group

Date: 05.09.2001

Was this article helpful?

0 0
DIY Battery Repair

DIY Battery Repair

You can now recondition your old batteries at home and bring them back to 100 percent of their working condition. This guide will enable you to revive All NiCd batteries regardless of brand and battery volt. It will give you the required information on how to re-energize and revive your NiCd batteries through the RVD process, charging method and charging guidelines.

Get My Free Ebook


Post a comment